Studio Visual Editor
In Studio’s visual editor, open the Poll message processor’s properties editor. Select Fixed frequency scheduler, then adjust the values of the fields according to the table below.
| Field | Default Value | Description | XML | 
|---|---|---|---|
Frequency  | 
1000  | 
Polling frequency, relative to time unit. When set to 0 or a negative value, it switches to the default.  | 
frequency="1000"  | 
Start Delay  | 
0  | 
Upon triggering the flow for the first time, Mule stalls the running of the poll for a specific amount of time. This time period is expressed in the same time units as the frequency.  | 
startDelay="0"  | 
Time unit  | 
MILLISECONDS  | 
The time unit for the frequency value. MILLISECONDS, SECONDS, MINUTES, HOURS, DAYS  | 
timeUnit="MILLISECONDS"  | 
XML Editor
In Studio’s XML editor, add a fixed-frequency-scheduler child element to your poll element. Configure the child element’s attributes according to the table below.
<poll doc:name="Poll">
  <fixed-frequency-scheduler frequency="1000" timeUnit="MILLISECONDS" startDelay="0"/>
  <sfdc:authorize config-ref="SalesforceGlobal" display="Salesforce1" doc:name="Salesforce1"/>
</poll>
| Attribute | Description | Example | 
|---|---|---|
  | 
Polling frequency, relative to time unit. When set to 0 or a negative value, it switches to the default.  | 
frequency="1000"  | 
  | 
The time unit for the frequency value. MILLISECONDS, SECONDS, MINUTES, HOURS, DAYS  | 
timeUnit="MILLISECONDS"  | 
  | 
Upon triggering the flow for the first time, Mule stalls the running of the poll for a specific amount of time. This time period is expressed in the same time units as the frequency.  | 
  | 